High frequency spark generator
Meet the requirements of Article 22.110 of GB4706.22-2008, used to test whether the flammable gas is discharged from the vents during the pyrolysis cleaning process. Parameters: Spark length: approx. 3mm Energy per spark: at least 0.5J Spark generation mode: bipolar output; peak voltage: ±7kv current: 40mA; 20kHz; ignition distance: 2-5mm adjustable
Introduction:
To meet the requirements of Article 22.110 of GB4706.22-2008, the button life tester is used to check whether the flammable gas is discharged from the ventilating port during the pyrolysis cleaning process.
parameter:
Spark length: about 3mm Energy per spark: at least 0.5J
Spark generation mode: bipolar output;
Peak voltage: ±7kv
Current: 40 mA; 20 kHz;
Ignition distance: 2-5mm adjustable
Previous: Wire soft winding test device
下一条: Key life tester