Probe 9 / Probe 10
The probe 9 satisfies the requirements of Clause 10.5 and the requirements shown in Figure 9 of GB 2099.1-2008/IEC 60884.1-2006 "Plug and socket for household and similar purposes - Part 1: General requirements"
I. Overview:
The probe 9 is made in accordance with the requirements of Clause 10.5 and Figure 9 of GB 2099.1-2008/IEC 60884.1-2006 "Plug and socket for household and similar purposes Part 1: General requirements"; probe 10 meets GB 2099.1-2008/IEC 60884.1-2006 "Plug-and-sockets for household and similar purposes - Part 1: General requirements", clause 10.5 of the defibrillation tester standard and the requirements shown in Figure 10.
Second, technical parameters:
Probe 9
1, the handle outer diameter ø30mm length 60mm (including the step outer diameter ø50mm length 5mm), the front rigid steel wire width 3mm, thickness 1mm, length 80mm, total length greater than 150mm;
2. When applying a force of 20N, the AA ́ face should be flush with BB ́.
Probe 10
1, the handle outer diameter ø30mm length 60mm (including the step outer diameter ø50mm length 5mm), the front end of the rigid steel wire ø1mm, length 80mm, the total length is greater than 150mm;