Photovoltaic module fire test equipment

Photovoltaic module fire test equipment

This equipment is designed for the fire test requirements of photovoltaic products and is designed according to the requirements of IEC61730-2 and ANSI/UL 730. Flame diffusion test and fuel block test can be realized.

Product Details

I. Overview:

This equipment is designed for the fire test requirements of photovoltaic products and is designed according to the requirements of IEC61730-2 and ANSI/UL 730. Flame diffusion test and fuel block test can be realized.

Two device configuration:

1 Two gas burners, the structure is: 1.12m long, inner diameter 50mm, outer diameter 60.3mm, stainless steel pipe, the pipe has 12.7mm and 910mm long groove. The burner is supplied with gas from both ends by a pipe having an inner diameter of 25 mm and an outer diameter of 33.4 mm;

2 test platform, the surface is made of high temperature resistant tiles, length 1300mm. Wide 1000mm, test angle adjustable, bottom supported by stainless steel table, height adjustable; high temperature isolation plate installed at the tail; drum drop tester

3 Simulated eaves and cornices, supported by stainless steel, adhered to high temperature insulation panels, and can withstand temperatures up to 1000 degrees; their dimensions are in full compliance with the requirements of Figure A1 of IEC61320-2;

4 air supply duct, width 2130mm, height 762mm, length 1500mm, distance from the ground is 1100mm, the pipe has adjustable fins to adjust the airflow direction; with two extension plates, the surface adheres to high temperature Insulation board, detachable, height 343mm;

5 with plywood, installed probe for measuring wind speed;

6 measuring wind speed device with 3 sets of TESTO, including: 3 thermal probes, wind speed transmitter, wind speed display table;

7 fan with frequency converter, can adjust the wind speed required to reach the test: km / h;

8 Burning block turning fixture, used for burning test of fire block A, B, C required for burning block, burning six faces of burning block according to the time required by the standard;

9 combustion chamber for the combustion of the fuel block before the fuel block test, equipped with a temperature measuring couple, which can test the temperature of the flame ejected by the gas burner;

10 equipped with 3 sets of fuel blocks for fire resistance grades A, B, C;

11 is equipped with a sample support frame.


Inquiry