Salt spray test machine
Scope of application: The salt spray test machine is used for the surface treatment of various materials, including coatings, electroplating, organic and inorganic coatings, anodizing, anti-rust oil and other anti-corrosion treatments to test its corrosion resistance, thus establishing the quality of the products. High temperature and high pressure water spray test device
Scope of application: The salt spray test machine is used for the surface treatment of various materials, including coatings, electroplating, organic and inorganic coatings, anodizing, anti-rust oil and other anti-corrosion treatments to test its corrosion resistance, thus establishing the quality of the products. High temperature and high pressure water spray test device
1. | YWX/Q-120B salt spray test machine | continuous Intermittent spray |
2. | YWX/Q-60B salt spray test machine | Continuous intermittent spray |
1 | Inner box size: 1 2 00* 10 0 0 *600(L*W*H)MM | |||
2 | Carton size: 20 00*1 2 00*1480(L*W*H)MM | |||
3 | power supply: Single phase 220V 3.5KW 50HZ | |||
Box material | ||||
1 | The test case body is made of light gray PVC board with a thickness of 8mm and a durable temperature of 50 °C. | |||
The edge is surrounded by a three-dimensional reinforcing thickness of 10mm, and the structure is firm. | ||||
2 | The test chamber cover is sealed with PVC impact-resistant plate with a thickness of 5mm. Inside and outside the edge | |||
The layer is thickened to prevent distortion due to long-term high temperature. Thickness 10mm | ||||
3 | Hide the integrated reagent refill bottle, easy to clean and easy to operate | |||
4 | The pressure air bucket is best insulated with SUS#304 stainless steel high pressure bucket. (Taiwan Electric Heating) | |||
5 | The sample placing table is made of 5mm temperature-resistant PVC board, which has strong bearing capacity. The test sample holder adopts plane indexing type, and the angle can be adjusted arbitrarily. | |||
The fog on the four sides is even, the fog is completely consistent, the test result is accurate, and the test sample is placed in a large amount. (can be customized according to customer's product requirements) | ||||
Technical basis | ||||
Operate according to JIS, ASTM, CNS, GB standard parameters | ||||
. Salt spray test: NSS ACSS | ||||
1 | Laboratory temperature | 35°C±1°C Fluctuation: ≤±1.0°C Uniformity: ≤2°C | ||
2 | Pressure air barrel temperature | 47°C±1°C | ||
Corrosion resistance test: CASS | ||||
1 | Laboratory temperature | 50°C±1°C Fluctuation: ≤±1.0°C Uniformity: ≤2°C | ||
2 | Pressure air barrel temperature | 63°C±1°C | ||
Air supply system | ||||
Air pressure is two adjustments | One section is roughly adjusted to 2Kg/cm 2 and the inlet air filter is provided with drainage function. | |||
The second section is precision adjusted 1Kg/cm 2 , 1 / 4 pressure gauge, showing precise and accurate | ||||
Spray method | ||||
a. The Bernut principle draws salt water and then atomizes, the atomization degree is uniform, and there is no obstruction crystallization, which ensures continuous testing. | ||||
b. The nozzle is made of Taiwan Taiwan floating tempered glass, which can adjust the spray volume and the spray angle. | ||||
c. The spray amount is adjustable from 1 to 2 ml/h (ml/2000px 2 /h standard requires 16 hours to average). The measuring cylinder is embedded in the installation and has a beautiful appearance. | ||||
Neat, easy to observe, reduce instrument installation space | ||||
d. Spray method: continuous spray | ||||
Heating system | ||||
Direct heating is adopted, and the heating rate is fast to reduce the standby time. When the temperature reaches, the constant temperature state is automatically switched, the temperature is accurate, and the power consumption is small. | ||||
Pure titanium heating tube, resistant to acid and alkali corrosion, long service life | ||||
Control System | ||||
1. | The laboratory and pressure tanks are all liquid crystal type double character temperature controllers, with microcomputer automatic calculation function, control error ±1.0 °C | |||
. The circuit board is treated with moisture and corrosion, high precision and long life. | ||||
2. | The test chamber heating tank uses a liquid expansion safety temperature controller 30 ~ 150 ° C (Korea Rainbow) | |||
3. | LCD digital display programmable time controller, power failure memory function 0.1S ~ 9999hr (1) | |||
4. | Timer 0~99hr | |||
5 | Relay (OMRON 1 group) | |||
6 | Rocker with light switch, can work 25,000 times in a row | |||
Watering system | ||||
The automatic and manual watering systems are used to automatically or manually replenish the pressure tank and the test room water level to prevent water shortage and high temperature damage to the instrument. | ||||
Defogging system | ||||
During the test and during the shutdown, the salt spray in the test chamber is removed to prevent the corrosion gas from flowing out of the damage chamber and other precision instruments. | ||||
Safety device | ||||
1. When the water level is low, the power is automatically cut off, and the safety warning light device lights up. | ||||
2. When the temperature is over temperature, the heater power is automatically turned off, and the safety warning light device lights up. | ||||
3. When the water level of the reagent (salt) is low, the safety warning light device lights up and alarms | ||||
4. Leakage protection function to prevent personal injury and instrument failure caused by line leakage or short circuit | ||||
Standard equipment | ||||
a. Shelf........................1 set | ||||
b. Metering cylinder........................2 | ||||
c. Temperature indicator pin..................2 pieces (optional) | ||||
d. Collector........................2 | ||||
e. Glass nozzles.................. 2 pieces (wear parts need to be replaced regularly) | ||||
f. Humidity cup........................1 | ||||
g. Filters........................2 (replaced regularly) | ||||
h. Spray tower........................2 sets | ||||
j. Defogging system.....................1 group | ||||
k. Automatic watering system..................1 group | ||||
annex | ||||
Test drug sodium chloride (Nacl) 500g 2 bottles | ||||
Operating instructions 1 copy | ||||
5L measuring cup 1 | ||||
Salinity meter 1 |
Scope of application: The salt spray test machine is used for the surface treatment of various materials, including coatings, electroplating, organic and inorganic coatings, anodizing, anti-rust oil and other anti-corrosion treatments to test its corrosion resistance, thus establishing the quality of the products. | ||||||
First, model and name: Salt spray test machine
| ||||||
Specifications | ||||||
1 | Inner box size: 9 00 *6 0 0 * 5 00(L*W*H)MM | |||||
2 | Carton size: 14 00* 8 00*1 0 80(L*W*H)MM | |||||
3 | power supply: Single phase 220V 2 KW 50HZ | |||||
Box material | ||||||
1 | The test case body is made of light gray P P plate with a thickness of 8mm and a durable temperature of 50 °C. | |||||
The edge is surrounded by a three-dimensional reinforcing thickness of 10mm, and the structure is firm. | ||||||
2 | The test chamber cover is sealed with PVC impact-resistant plate with a thickness of 5mm. Inside and outside the edge | |||||
The layer is thickened to prevent distortion due to long-term high temperature. Thickness 10mm | ||||||
3 | Hide the integrated reagent refill bottle, easy to clean and easy to operate | |||||
4 | The pressure air bucket is best insulated with SUS#304 stainless steel high pressure bucket. (Taiwan Electric Heating) | |||||
5 | The sample placing table is made of 5mm temperature-resistant PVC board, which has strong bearing capacity. The test sample holder adopts plane indexing type, and the angle can be adjusted arbitrarily. | |||||
The fog on the four sides is even, the fog is completely consistent, the test result is accurate, and the test sample is placed in a large amount. (can be customized according to customer's product requirements) | ||||||
Technical basis | ||||||
Operate according to JIS, ASTM, CNS, GB standard parameters | ||||||
Salt spray test: NSS ACSS | ||||||
1 | Laboratory temperature | 35°C±1°C Fluctuation: ≤±1.0°C Uniformity: ≤2°C | ||||
2 | Pressure air barrel temperature | 47°C±1°C | ||||
Corrosion resistance test: CASS | ||||||
1 | Laboratory temperature | 50°C±1°C Fluctuation: ≤±1.0°C Uniformity: ≤2°C | ||||
2 | Pressure air barrel temperature | 63°C±1°C | ||||
Air supply system | ||||||
Air pressure is two adjustments | One section is roughly adjusted to 2Kg/cm 2 and the inlet air filter is provided with drainage function. | |||||
The second section is precision adjusted 1Kg/cm 2 , 1 / 4 pressure gauge, showing precise and accurate | ||||||
Spray method | ||||||
a. The Bernut principle draws salt water and then atomizes, the atomization degree is uniform, and there is no obstruction crystallization, which ensures continuous testing. | ||||||
b. The nozzle is made of Taiwan Taiwan floating tempered glass, which can adjust the spray volume and the spray angle. | ||||||
c. The spray amount is adjustable from 1 to 2 ml/h (ml/2000px 2 /h standard requires 16 hours to average). The measuring cylinder is embedded in the installation and has a beautiful appearance. | ||||||
Neat, easy to observe, reduce instrument installation space | ||||||
d. Spray method: continuous spray | ||||||
Heating system | ||||||
Direct heating is adopted, and the heating rate is fast to reduce the standby time. When the temperature reaches, the constant temperature state is automatically switched, the temperature is accurate, and the power consumption is small. | ||||||
Pure titanium heating tube, resistant to acid and alkali corrosion, long service life | ||||||
Control System | ||||||
1. | The laboratory and pressure tanks are all liquid crystal type double character temperature controllers, with microcomputer automatic calculation function, control error ±1.0 °C | |||||
. The circuit board is treated with moisture and corrosion, high precision and long life. | ||||||
2. | The test chamber heating tank uses a liquid expansion safety temperature controller 30 ~ 150 ° C (Korea Rainbow) | |||||
3. | LCD digital display programmable time controller, power failure memory function 0.1S ~ 9999hr (1) | |||||
4. | Timer 0~99hr | |||||
5 | Relay (OMRON 1 group) | |||||
6 | Rocker with light switch, can work 25,000 times in a row | |||||
Watering system | ||||||
The automatic and manual watering systems are used to automatically or manually replenish the pressure tank and the test room water level to prevent water shortage and high temperature damage to the instrument. | ||||||
Defogging system | ||||||
During the test and during the shutdown, the salt spray in the test chamber is removed to prevent the corrosion gas from flowing out of the damage chamber and other precision instruments. | ||||||
Safety device | ||||||
1. When the water level is low, the power is automatically cut off, and the safety warning light device lights up. | ||||||
2. When the temperature is over temperature, the heater power is automatically turned off, and the safety warning light device lights up. | ||||||
3. When the water level of the reagent (brine) is low, the safety warning light device lights up and alarms. | ||||||
4. Leakage protection function to prevent personal injury and instrument failure caused by line leakage or short circuit | ||||||
Standard equipment | ||||||
a. Shelf........................1 set | ||||||
b. Metering cylinder........................2 | ||||||
c. Temperature indicator pin..................2 pieces (optional) | ||||||
d. Collector........................2 | ||||||
e. Glass nozzle........................ 1 stick (wear parts need to be replaced regularly) | ||||||
f. Humidity cup........................1 | ||||||
g. Filters........................2 (replaced regularly) | ||||||
h. Spray tower........................ 1 set | ||||||
j. Defogging system.....................1 group | ||||||
k. Automatic watering system..................1 group | ||||||
annex | ||||||
Test drug sodium chloride (Nacl) 500g 2 bottles | ||||||
Operating instructions 1 copy | ||||||
5L measuring cup 1 | ||||||
Salinity meter 1 | ||||||
Installation requirements
| a. Machine use environmental conditions: * Temperature: 5 ° C ~ 35 ° C * Relative humidity: less than 85% * Direct radiation without direct sunlight or other heat sources *No high concentration of dust and corrosive substances around b. The machine enters the doorway or the passage elevator, etc., please confirm whether you can enter c. Machine power supply conditions: *Voltage: 220±22 V *Frequency: 50±1 Hz d. Ensure that the user site can be put into use directly without additional configuration |